SKUDO ONE: the ultimate solution.

Introducing the SKUDO ONE 60 Convertible, the Uninterruptible Power Supply (UPS) in a convertible 19″ rack / tower format with On-Line double conversion technology that ensures total protection for your critical devices. Thanks to an architecture that fully isolates the loads from the mains, it delivers a perfectly sinusoidal, stable voltage, eliminating every disturbance (surges, micro-interruptions, interference) and ensuring zero transfer time in the event of a blackout.

Ideal for servers, workstations, network equipment and medical systems, this UPS combines 2,000VA/1,000W of power with smart management. The LCD display and communication interfaces (USB/RS232) provide full control, including automatic shutdown of protected computers via the free software. Advanced features such as ECO mode for energy saving, fast battery charging and programmable outputs make it a versatile and reliable solution.

With a convertible, quiet format (≤50 dB) that installs in a rack cabinet (2U) or upright, CE and UL certifications and a 2-year warranty, the SKUDO ONE 60 Convertible is the ultimate choice for safety and business continuity in the server room, the office or any professional environment.

Out of stock

Compare

Description

SKUDO ONE 60 Convertible: excellence in power protection

Total protection for your critical operations

The SKUDO ONE 60 Convertible represents the pinnacle of UPS (Uninterruptible Power Supply) technology for protecting servers, rack cabinets, network systems and any equipment that cannot afford even a moment of interruption or a mains disturbance. Built on proven On-Line Double Conversion technology, it ensures your devices always receive perfect, stable and clean power, regardless of the condition of the public grid. Thanks to its convertible 19″ rack / tower format, it installs just as easily in a 2U rack cabinet or standing upright.

While traditional UPS units interrupt power for a few milliseconds when switching to battery, the On-Line technology of the SKUDO ONE 60 Convertible delivers a zero transfer time. The inverter is always running, continuously feeding the load with a perfect sine wave, guaranteeing absolute continuity and protecting against every mains problem: blackouts, overvoltages, undervoltages, frequency disturbances and electrical noise.


Key benefits and features

  • On-Line Double Conversion technology: the only technology that delivers a perfectly sinusoidal output with zero interruption, fully isolating the protected equipment from mains disturbances.
  • Smart management and full control: equipped with a backlit LCD display for real-time monitoring and USB and RS232 communication interfaces. The free management software, available on our website, enables remote monitoring, orderly automatic shutdown of systems and advanced configuration.
  • Maximum efficiency and flexibility: ECO mode to reduce energy consumption, programmable output sockets, frequency converter function (50/60 Hz) and adjustable output voltage (from 200V to 240V) directly from the display.
  • Complete protection: built-in protection against overloads, short circuits and voltage surges. Advanced EMI/RFI filters suppress radio interference.
  • Long-lasting batteries: an Advanced Battery Management (ABM) system optimises performance and extends battery life, also supporting fast charging.
  • Flexible installation and certified design: thanks to its mechanical engineering and LCD panel that rotates by 90°, it can be installed either in a 19″ rack cabinet (2U) or as a tower. Built with high-quality, recyclable materials, it holds the main international certifications (CE, UL, ISO9001) and is approved by leading hardware manufacturers.

Key technical details

Parameter Specification
Technology On-Line Double Conversion
Installation 19″ rack (2U) or tower
Power 6,000 VA / 3,000 W
Input/Output Voltage Single-phase 230V
Output Waveform Pure sine wave (<4% THD)
Typical Backup Time Approx. 10 minutes
Recharge Time 3 hours (to 90% of capacity)
Interfaces USB, RS232, SNMP (optional)
Outputs 6 IEC sockets (3 programmable) + 1 IEC C19
Noise ≤ 50 dB at 1 metre
Dimensions (WxDxH) 438 x 630 x 88 mm (2U)
Net Weight 27.5 kg
Warranty 2 years

Why choose the SKUDO ONE 60 Convertible?

Choosing the SKUDO ONE 60 Convertible means investing in maximum safety and business continuity.
It is the ideal solution for:

  • Rack cabinets and server rooms: takes up just 2U in a 19″ cabinet alongside servers, switches and network equipment, keeping them running without interruption and allowing a safe shutdown during an extended blackout.
  • Offices and professionals: in tower position it protects computers, network printers and essential devices, preventing data loss and hardware damage.
  • Special applications: perfect for POS systems, medical equipment, laboratories and any application that requires flawless, stable power.

With its convertible rack/tower format, quiet operation and a 2-year warranty, the SKUDO ONE 60 Convertible offers unbeatable value for money in high-end power protection.

Immediate Availability | 24-Month Warranty | Specialist Technical Support

Additional information

Weight 29,70 kg
Dimensions 76 × 60 × 20 cm
Manufacturer:

ON LITE S.r.l.

Product code:

SKOC60

Typology:

Uninterruptible Power Supply – UPS

Technology:

On Line double conversion

Operating voltage:

One phase Input and Output 230Vac

Technical Specifications

Technical Data Sheet

 Model SKUDO One 60 Convertible
 Technology On-Line Double Conversion
 Power
 IT load (VA) 6,000
 Electrical load (VA) 4,250
 Electrical load (W) 3,000
 Input
 Phases Single-phase + Earth
 Minimum transfer voltage (Vac) 160 / 140 / 120 / 110 ±5% – depending on the applied load: 100-80% / 80-70% / 70-60% / 60-0%
 Minimum return voltage (Vac) 175 / 155 / 135 / 125 ±5% – depending on the applied load: 100-80% / 80-70% / 70-60% / 60-0%
 Maximum transfer voltage (Vac) 300 ±5%
 Maximum return voltage (Vac) 290 ±5%
 Frequency tolerance (Hz) 40 to 70
 Power factor (cos φ) ≧0.99 at 230 Vac input and 100% load
 Total harmonic distortion (THD) ≦5% with input voltage between 205 and 245 Vac
THDu <1.6% with linear input and load
 Output
 Selectable voltage (Vac) 200 / 208 / 220 / 230 / 240
 Voltage tolerance ±1% in battery mode
 Frequency synchronised with mains (Hz) 50: 47 to 53 – 60: 57 to 63
 Frequency in battery mode (Hz) 50 or 60 ±0.1 Hz
 Current at 230 Vac (A) 13.10
 Waveform Pure sine wave
 Crest factor  3:1
 Harmonic distortion (THD) ≦2% with linear load – ≦4% with non-linear load
 Transfer time, mains to battery (ms) Zero
 Transfer time, inverter to bypass (ms) <4
 Battery
 Type Sealed lead-acid, maintenance-free
 No. of batteries 6
 Capacity (Ah) 9
 Voltage (Vdc) 72
 Typical backup time (min) 10
 Recharge time (hours) 3 to 90% of the internal battery’s rated capacity after a full discharge, with a 2A charging current
 Charging current 2A default, adjustable up to 8A
 Charging voltage (Vdc) 82.1 ±1%
 Protections
 Short circuit Mains fuse – electronic protection in inverter mode
 Batteries End-of-discharge shutdown at 1.65 V/cell
 Radio interference Compliant with CE marking and FCC standard
 PC interface
 USB and RS232 Software compatible with the most common operating systems
 Environmental conditions
 Temperature (°C) 0 to +40
 Humidity Up to 95%, non-condensing
 Noise level
 dBA at 1 metre ≦50
 Dimensions and weights
 Dimensions (WxDxH mm) 438 x 630 x 88 (2U)
 Net weight (kg) 27.50
 Packaging dimensions (WxDxH mm) 760 x 600  x 200
 Gross weight (kg) 29.70
 Input connection
 Plug 1 cable supplied with Italian plug
 Terminal block Not available
 Output connection
 No. of IEC320 sockets 6, of which 3 programmable + 1 IEC320 C19
 Terminal block Not available
 No. of cables supplied 1 cable with IEC320 connector

Technical notes:

  • The UPS output power is derated to 80% when it operates as a frequency converter or when the output voltage is set to 200 or 208 Vac.
  • A maximum altitude of 1,000 metres must be maintained for correct UPS operation at full load. If the UPS is used at high altitude, reduce the connected load. The altitude derating factor for the connected loads during normal UPS operation is shown in the following table:
Altitude (metres) Derating factor
1,000 1.00
1,500 0.95
2,000 0.91
2,500 0.86
3,000 0.82
3,500 0.78
4,000 0.74
4,500 0.70
5,000 0.67
Notes:
The values refer to a dry air density of 1.225 kg/m3 at sea level at a temperature of +15°C.
Since fans lose efficiency at higher altitudes, UPS units with forced-air cooling are derated because they can no longer properly dissipate the heat they produce.

Manuale d'uso

Manuale operativo allegato agli UPS serie SKUDO ONE modelli dal 20 al 60

Visualizza o scarica il manuale SKUDO ONE